Resona
ZONE Sonography® Technology
ZONE Sonography® overcomes limitations of the traditional beamformer process, as well as expands the current and future possibilities of patient-friendly modular ultrasound. This constitute
a fundamentally new software image formers,
the zone-wise detection of the echo data,
a long-term storage of original probe information as well as
the implementation of commercially available, ever-increasing processing power
the technological bases for the following example already with Zone Sonography®realized industry novelty:
ULTRASOUND WITH RESPONSIBILITY
Everyone is different. Concerning an improved diagnostic accuracy, the system takes this into depiction with ZST+. Instead to assume from the conventional default standard (1.540 m/s), the technology is now for the first time able to use the individual patient-dependent speed of sound for imaging.
Transforming ultrasound metrics from conventional beamforming to channel data based processing, ZST+ is able to deliver multiple imaging advances: Advanced Acoustic Acquisition, Dynamic Pixel Focusing, Sound Speed Compensation, Advanced Image Processing and Total Recall Imaging.
DYNAMIC PIXEL FOCUSING
Dynamic Pixel Focusing technology allows Resona 7 to achieve extreme uniformity in pixel level through the whole field of view. Therefore, there is no longer the need to frequently adjust the focal positions to achieve uniformity across patient exams.
ADVANCED ACOUSTIC ACQUISITION
By transmitting and receiving a relatively smaller number of large zones, Advanced Acoustic Acquisition extracts more information from each acquisition, 10 times faster than a conventional line-by-line beamforming method.
and guarantee you’ll love working with our team. Let us know how we can assist you today.
SOUND SPEED COMPENSATION
By retrospectively analyzing complete channel data stored in channel data memory, the Resona 7 is able to intelligently choose the optimal sound speed to improve image accuracy even with tissue variation, allowing for adaptive tissue-specific optimization.
ADVANCED IMAGE PROCESSING
By multiple and retrospective channel data processing, it makes the best use of acoustic information for image improvement.
HD Scope: higher definition image within ROI.
Coherent Spatial Synthesis: further improved image quality.
RESONA
Research Features of ZST+
Besides of the above described Key-Features of ZST+, there are more very important properties of this pioneering technology. We call this kind of characteristics the Research Features of ZST+.
V Flow visualisation of complex microhemodynamics
Fusion Imaging with respiration compensation
RIMT medical method to detect CVDs
CEUS - UWN Mindray´s 2nd generation